Full Range Photodiode Array UV-Vis-NIR Spectroradiometer
Working with a spectroradiometer in the lab is necessary for many applications that require handling sensitive materials that cannot maintain their integrity outside of lab conditions, such as calibration transfer or testing solar simulators, and scanning materials that require sanitary conditions. Spectral Evolution offers a variety of spectroradiometers designed with these delicate tasks in mind.
Spectral Evolution’s SR-Series Laboratory spectroradiometers deliver high sensitivity with a high signal-to-noise ratio and an unmatched wide dynamic range. Our spectroradiometers are calibrated for solar radiance to generate a spectral match report for measuring class performance as per IEC60904-9/ASTM E927-05, making them especially useful for measuring continuous or pulse solar simulators.
Full Range Photodiode Array UV-Vis-NIR Spectroradiometer
Working with a spectroradiometer in the lab is necessary for many applications that require handling sensitive materials that cannot maintain their integrity outside of lab conditions, such as calibration transfer or testing solar simulators, and scanning materials that require sanitary conditions. Spectral Evolution offers a variety of spectroradiometers designed with these delicate tasks in mind.
Spectral Evolution’s SR-Series Laboratory spectroradiometers deliver high sensitivity with a high signal-to-noise ratio and an unmatched wide dynamic range. Our spectroradiometers are calibrated for solar radiance to generate a spectral match report for measuring class performance as per IEC60904-9/ASTM E927-05, making them especially useful for measuring continuous or pulse solar simulators.
Common Laboratory Applications:
- Radiometric calibration transfer
- LED, laser and light source metrology
- Solar radiance and irradiance measurements
- Solar simulator test and classification
- Art & heritage analysis
- Food & pharmaceuticals identification
- Plastics identification
- Remote sensing applications

Model | CalibraSpec™ 6500A | CalibraSpec™ 4500A | RS-5400 | SR-2500 | SR-1901PT | PrimaSpec™ |
Spectral Range | 350-2500 nm | 350-2500 nm | 350-2500 nm | 350-2500 nm | 280-1900 nm | 350-2500 nm |
Spectral Resolution | 1.5 nm @ 700 nm 3 nm @ 1500 nm 3.8 nm @ 2100 nm | 3 nm @ 350-1000 nm 8 nm @ 1500 nm 6 nm @ 2100 nm | 2.5 nm @ 700 nm 5.5 nm @ 1500 nm 5.8 nm @ 2100 nm | 3.5 nm (350-1000 nm) 22 nm @ 1500 nm 22 nm @ 2100 nm | 4 nm (280-1000 nm) 10 nm (1000-1900 nm) | 4 nm (350-1000 nm) 10 nm @ 1500 nm 10 nm @ 2100 nm |
Sampling Bandwidth (nm) | 2151 Sampling channels | Data output in 1 nm increments | 2151 Sampling channels | Data output in 1 nm increments | 2151 Sampling channels | Data output in 1 nm increments | 2151 Sampling channels | Data output in 1 nm increments | 1621 Sampling channels | Data output in 1 nm increments | 2151 Sampling channels | Data output in 1 nm increments |
Spectrometer Type | 3 Diffraction Gratings | 3 Diffraction Gratings | 3 Diffraction Gratings | 2 Diffraction Gratings | 2 Diffraction Gratings | - |
Detector(s) | 1024-element UV-enhanced TE-cooled Si Array ---------- 512-element TE-cooled InGaAs array ---------- 512-element TE-cooled extended InGaAs array | 512-element UV-enhanced TE-cooled Si Array ---------- 256-element TE-cooled InGaAs array ---------- 256-element TE-cooled InGaAs array | 1024-element UV-enhanced Si Array ---------- 512-element TE-cooled InGaAs array ---------- 512-element TE-cooled extended InGaAs array | 512-element UV-enhanced Si Array ---------- 256-element TE-cooled extended InGaAs arrays | 512-element UV-enhanced Si Array ---------- 256-element TE-cooled extended InGaAs array | 512-element Si Array (350-1000 nm) ---------- 256-element extended wavelength array (1000-1900 nm) |
Calibration | Factory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection) | Factory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection) | Factory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection) | Factory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection) | Factory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection) | - |
Noise Equivalence Radiance W/cm2/nm/sr | 0.4x10-9 @ 400 nm 0.2x10-9 @ 1500 nm 2.0x10-9 @ 2100 nm | 0.2x10-9 @ 400 nm 0.2x10-9 @ 700 nm 0.9x10-9 @ 900 nm 1.2x10-9 @ 1500 nm 1.8x10-9 @ 2100 nm | 0.3x10-9 @ 400 nm 0.1x10-9 @ 1500 nm 2.5x10-9 @ 2100 nm | 0.8x10-9 @ 400 nm 1.5x10-9 @ 1500 nm 1.8x10-9 @ 2100 nm | 0.8x10-9 @ 400 nm 1.2x10-9 @ 1500 nm | - |
Stray Light | ≤0.1%; VNIR: <0.03%; SWIR<0.02% | ≤0.1%; VNIR: <0.03%; SWIR<0.02% | ≤0.1%; VNIR: <0.03%; SWIR<0.02% | ≤0.1%; VNIR: <0.03%; SWIR<0.02% | ≤0.1%; VNIR: <0.03%; SWIR<0.02% | - |
Software Included | DARWin™ Data Acquisition Data output in ASCII format for easy post processing. Compatible with: All post-processing software, EZ-ID™ software for instant identification & spectral library building and Eigenvector chemometrics modeling software. | DARWin™ Data Acquisition Data output in ASCII format for easy post processing. Compatible with: All post-processing software, EZ-ID™ software for instant identification & spectral library building and Eigenvector chemometrics modeling software. | DARWin™ Data Acquisition Data output in ASCII format for easy post processing. Compatible with: All post-processing software, EZ-ID™ software for instant identification & spectral library building and Eigenvector chemometrics modeling software. | DARWin™ Data Acquisition Data output in ASCII format for easy post processing. Compatible with: All post-processing software, EZ-ID™ software for instant identification & spectral library building and Eigenvector chemometrics modeling software. | DARWin™ Data Acquisition Data output in ASCII format for easy post processing. Compatible with: All post-processing software, EZ-ID™ software for instant identification & spectral library building and Eigenvector chemometrics modeling software. | DARWin™ Data Acquisition Data output in ASCII format for easy post processing. Compatible with: All post-processing software, EZ-ID™ software for instant identification & spectral library building and Eigenvector chemometrics modeling software. |
Power | 12V, 33W | 7.5V, 30W | 7.5V, 33W | 7.5V, 15W | 7.5V, 15W | 7.5V, 23W |
Dimensions (millimeters | inches) | 315 x 221 x 112 mm | 12.4 x 8.7 x 4.4 in | 12.4"x 8.7"x 4.4" | 12.4"x 8.7"x 4.4" | 8.5" x 11" x 3.5" | 8.5" x 11" x 3.5" | 8.5in x 12in x 3.5in (215mm x 305mm x 89mm) |
Weight | 12.64 lbs | 12.64 lbs | 12.64 lbs | 8.52 lbs | 7.52 lbs | 7.3lbs (3.3kg) |
Interface | USB, Wireless Bluetooth® Connection | USB, Wireless Bluetooth® Connection | USB, Wireless Bluetooth® Connection | USB, Wireless Bluetooth® Connection | USB, Wireless Bluetooth® Connection | USB Connection |
Integration Time | 1 - 1000 ms | 1 - 1000 ms | 1 - 1000 ms | 1 - 1000 ms | 1 - 50 ms | - |
Max Radiance | VNIR: 10 x Solar; SWIR: 2 x Solar | VNIR: 10 x Solar; SWIR: 2 x Solar | VNIR: 10 x Solar; SWIR: 2 x Solar | VNIR: 10 x Solar; SWIR: 2 x Solar | VNIR: 10 x Solar; SWIR: 2 x Solar | - |
Wavelength Reproducibility (nm) | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
Wavelength Accuracy (nm) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Automatic Exposure | ✅ | ✅ | ✅ | ✅ | ✅ | - |
Shutter for Dark Scans | ✅ | ✅ | ✅ | ✅ | ✅ | - |
TTL & Phototriggering for pulsed measurement | No | No | No | No | Yes | - |