Full Range Photodiode Array UV-Vis-NIR Spectroradiometer

Working with a spectroradiometer in the lab is necessary for many applications that require handling sensitive materials that cannot maintain their integrity outside of lab conditions, such as calibration transfer or testing solar simulators, and scanning materials that require sanitary conditions. Spectral Evolution offers a variety of spectroradiometers designed with these delicate tasks in mind.

Spectral Evolution’s SR-Series Laboratory spectroradiometers deliver high sensitivity with a high signal-to-noise ratio and an unmatched wide dynamic range. Our spectroradiometers are calibrated for solar radiance to generate a spectral match report for measuring class performance as per IEC60904-9/ASTM E927-05, making them especially useful for measuring continuous or pulse solar simulators.

Full Range Photodiode Array UV-Vis-NIR Spectroradiometer

Working with a spectroradiometer in the lab is necessary for many applications that require handling sensitive materials that cannot maintain their integrity outside of lab conditions, such as calibration transfer or testing solar simulators, and scanning materials that require sanitary conditions. Spectral Evolution offers a variety of spectroradiometers designed with these delicate tasks in mind.

Spectral Evolution’s SR-Series Laboratory spectroradiometers deliver high sensitivity with a high signal-to-noise ratio and an unmatched wide dynamic range. Our spectroradiometers are calibrated for solar radiance to generate a spectral match report for measuring class performance as per IEC60904-9/ASTM E927-05, making them especially useful for measuring continuous or pulse solar simulators.

Common Laboratory Applications:

  • Radiometric calibration transfer
  • LED, laser and light source metrology
  • Solar radiance and irradiance measurements
  • Solar simulator test and classification
  • Art & heritage analysis
  • Food & pharmaceuticals identification
  • Plastics identification
  • Remote sensing applications

Model

SR-6500(A)

SR-4500(A)

RS-5400

SR-3500

SR-3501

SR-1901

SR-1901PT


Spectral Range

350-2500nm

350-2500nm


350-2500nm

350-2500nm

280-2500nm

280-1900nm

280-1900nm

Spectral Resolution


1.5nm@700nm

3nm@1500nm

3.8nm@2100nm

3nm@700nm

8nm@1500nm

6nm@2100nm

2.5nm@700nm

5.5nm@1500nm

5.8nm@2100nm

2.8nm@700nm

8nm@1500nm

6nm@2100nm

4nm (280-1000nm) 9.5nm@1500nm

7.0nm@2100nm

4nm (280-1000nm)

10nm (1000-1900nm)

4nm (280-1000nm)

10nm (1000-1900nm)

Sampling Bandwidth (nm)

Data output in 1nm increments; 2151 channels reported


Data output in 1nm increments; 2151 channels reported

Data output in 1nm increments; 2151 channels reported

Data output in 1nm increments; 2151 channels reported

Data output in 1nm increments; 2221 channels reported

Data output in 1nm increments; 1621 channels reported

Data output in 1nm increments; 1621 channels reported

Spectrometer Type


3 Diffraction Gratings


3 Diffraction Gratings

3 Diffraction Gratings

3 Diffraction Gratings

3 Diffraction Gratings

2 Diffraction Gratings

2 Diffraction Gratings

Detector(s)

1024-element UV-enhanced TE-cooled Si Array

----------

512-element TE-cooled InGaAs array

----------

512-element TE-cooled extended InGaAs array

512-element UV-enhanced TE-cooled Si Array

----------

Two 256-element TE-cooled extended InGaAs arrays

1024-element UV-enhanced Si Array

----------

512-element TE-cooled InGaAs array

----------

512-element TE-cooled extended InGaAs array

512-element UV-enhanced Si Array

----------

Two 256-element TE-cooled extended InGaAs arrays

512-element UV-enhanced Si Array

----------

Two 256-element TE-cooled extended InGaAs arrays

512-element UV-enhanced Si Array

----------

256-element TE-cooled extended InGaAs array

512-element UV-enhanced Si Array

----------

256-element TE-cooled extended InGaAs array

Calibration

Factory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection)

Factory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection)

Factory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection)

Factory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection)

Factory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection)

Factory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection)

Factory calibrated for radiance and/or irradiance using NIST traceable source (depending upon optics selection)

Noise Equivalence Radiance

W/cm2/nm/sr

(1.2m fiber optic)

0.8x10-9 @400nm
0.3x10-9 @1500nm
5.8x10-9 @2100nm

0.2x10-9 @400nm

0.2x10-9 @700nm

0.9x10-9 @900nm

1.2x10-9 @1500nm

1.8x10-9 @2100nm

0.3x10-9 @400nm

0.1x10-9 @1500nm

2.5x10-9 @2100nm

0.8x10-9 @400nm

1.2x10-9 @1500nm

1.8x10-9 @2100nm

0.8x10-9 @400nm

1.2x10-9 @1500nm

1.8 x10-9 @2100nm

0.8x10-9 @400nm

1.2x10-9 @1500nm

0.8x10-9 @400nm

1.2x10-9 @1500nm

Stray Light

≤0.1%; VNIR: <0.03%; SWIR<0.02%

≤0.1%; VNIR: <0.03%; SWIR<0.02%

≤0.1%; VNIR: <0.03%; SWIR<0.02%

≤0.1%; VNIR: <0.03%; SWIR<0.02%

≤0.1%; VNIR: <0.03%; SWIR<0.02%

≤0.1%; VNIR: <0.03%; SWIR<0.02%

≤0.1%; VNIR: <0.03%; SWIR<0.02%

Software Included

DARWin™ SP Data Acquisition

DARWin™ SP Data Acquisition

DARWin™ SP Data Acquisition

DARWin™ SP Data Acquisition

DARWin™ SP Data Acquisition

DARWin™ SP Data Acquisition

DARWin™ SP Data Acquisition

Power

7.5V, 33W

7.5V, 30W

7.5V, 33W

7.5V, 23W

7.5V, 23W

7.5V, 15W

7.5V, 15W

Dimensions

12.4"x 8.7"x 4.4"

8.5"x 13"x 5"

12.4"x 8.7"x 4.4"

8.5" x 11" x 3.5"

8.5" x 11" x 3.5"

8.5" x 11" x 3.5"

8.5" x 11" x 3.5"

Weight

12.64 lbs

12.26 lbs

12.64 lbs

8.52 lbs

8.52 lbs

7.52 lbs

7.52 lbs

Interface

USB, Wireless Connection

USB, Wireless Connection

USB, Wireless Connection

USB, Wireless Connection

USB, Wireless Connection

USB, Wireless Connection

USB, Wireless Connection

Integration Time

1 - 1000 ms

1 - 1000 ms

1 - 1000 ms

1 - 1000 ms

1 - 1000 ms

1 - 1000 ms

1 - 50 ms

Match Radiance

VNIR: 10 x Solar; SWIR: 2 x Solar

VNIR: 10 x Solar; SWIR: 2 x Solar

VNIR: 10 x Solar; SWIR: 2 x Solar

VNIR: 10 x Solar; SWIR: 2 x Solar

VNIR: 10 x Solar; SWIR: 2 x Solar

VNIR: 10 x Solar; SWIR: 2 x Solar

VNIR: 10 x Solar; SWIR: 2 x Solar

Wavelength Reproducibility (nm)

0.1

0.1

0.1

0.1

0.1

0.1

0.1

Wavelength Accuracy (nm)

0.5

0.5

0.5

0.5

0.5

0.5

0.5

Automatic Exposure

Shutter for Dark Scans

TTL & Phototriggering for pulsed measurement

No

No

No

No

No

No

Yes

All instruments in the Spectral Evolution Laboratory SR Series feature:

  • Fast and easy operation

  • Auto-exposure, auto-scaling, and auto-dark shutter

  • Compact, lightweight design – easy to fit into your lab

  • NIST traceable calibration for irradiance or spectral radiance measurements and calibration transfer

  • No internal fiber optics or movable gratings to break, drift, or fail during mission-critical experiments

  • Fiber optic or optional integrating sphere input

  • Exclusive DARWin™ SP Data Acquisition and Analysis software for one-touch, full range spectroscopic analysis of samples